"electrical control equipment"
3 contattore 3P 4P 9A~95A 115~410A AC-3 AC-1 24V 110V 230V 380V di CA di 1Phase LC1D
Schneider Electric LC1D AC Contactor 3P, 4P 9A~95A,115~410A,AC-3 AC-1 24V,110V,230V,380V Characteristic • Current range 09~620A; • AC, DC control coil is optional (DC coil to 38A); • Different types of starters are available: standard motor start contactors, reversible contactors, star-delta ...
Componenti modulari di bassa tensione del contattore di Ict Acti9 1-4 Palo 230V/400V 16 25 40 64 100A
Schneider Electric iCT Acti9 Modular Contactor 1,2,3,4 Pole 230V/400V Home or Industrial Use 16,25,40,64,100A IEC61095 characteristic Product standard IEC61095/GB17885 Product Certification CCC CE Product poles 1,2,3,4 Rated current 16,25,40A,63A,100A Main contact type NO, NC, NO+NC Protection class ...
Contattore termico del relè di sovraccarico del contattore del motore a corrente alternata di LRD10C LED35C che mette 4~6A corrente 30~38A
Schneider Electric LRD10C, LED35C Thermal Overload Relay For Contactor Setting Current 4~6A, 30~38A, 400V IEC947-4-1 characteristic • Manual/automatic reset • Pre-wired components • Independently mounted terminal block • Remote electrical reset • 45mm wide to 18.5Kw, 55mm wide from 15Kw to 30Kw, can ...
SPD protettore di impulso di 3 fasi, dispositivi di protezione domestici dell'impulso 1 2 3 4 Palo 230V/400V Imax20 40 65kA
Schneider Electric iST Surge Protection Device SPD 1,2,3,4 Pole 230V/400V Home or Industrial Use Imax=20,40,65kA Characteristic * IEC test category: Class II test (8/20us) * Compliance with standards: GB 18802.1 * Maximum sustainable operating voltage Uc: 340V * Maximum discharge current Imax: 65/40...
Metro multifunzionale di CA 1A 5A Digital, 380/400V 3 interfaccia del misuratore di potenza RS485 di fase
Chint PD666-S4, PD7777-S4 series digital multi-functional meter 3 380/400V phase with RS-485 communication interface PD666-S4 series three phase digital multi-functional meter Summary&application: PD666-S4 series three phase digital multi-functional meter is designed for the demand of power ...
CA neutrale 10A del relè di protezione di guasto RV8-03~08
RV8-03~08 AC 3 Phase Voltage Controller Phase Sequence and Failure Protection Relay 10A General Applications -Control for connection of moving equipment(site equipment,agricultural equipent,refrigerated trucks). -Control for protection of persons and equipment against the consequences of reverse ...
1 2 3 dispositivo di protezione dell'impulso di 4 Pali SPD, fase industriale del protettore di impulso 3 1 fase 230V/400V
Chint Over-voltage Under-voltage Protection Relay 230V/400V Home or Industrial Use in 1-phase or 3-phase General NU6-II series surge protector is suitable for AC 50Hz, rated voltage 230V/400V three-phase power distribution and control system, meets SPD level test, used to suppress transient ...
Fase del dispositivo di protezione dell'impulso delle componenti di bassa tensione di IEC 61643 SPD 1or 3
Chint NXU-II Surge Protection Device SPD 1,2,3,4 Pole 230V/400V Home or Industrial Use in IEC 61643 General NUX-II series surge protector is suitable for AC 50Hz, rated voltage 230V/400V three-phase power distribution and control system, meets SPD level test, used to suppress transient overvoltage ...
Componenti modulari 1 di bassa tensione del contattore di CA 2 3 4 Palo 20A 25A 40A 63A 230V/400V
Chint NCH8 Modular AC Contactor 1,2,3,4 Pole 20A,25A,40A,63A 230V/400V Home or Industrial Use IEC 61095 General Product standard IEC61095/GB17885 Product Certification CCC CE Product poles 1,2,3,4 Rated current 16,25,40A,63A,100A Main contact type NO, NC, NO+NC Protection class IP20B (terminal), ...
1 3 4 modulari contattore di CA di 2 Pali, IEC domestico 61095 del contattore 20A 25A 40A 63A 230V/400V di CA
NCH8 1,2,3,4 Pole 20A,25A,40A,63A 230V/400V Modular AC Contactor Chint Home or Industrial Use IEC 61095 General Product standard IEC61095/GB17885 Product Certification CCC CE Product poles 1,2,3,4 Rated current 16,25,40A,63A,100A Main contact type NO, NC, NO+NC Protection class IP20B (terminal), ...
IL CA di CJX2-N che inverte il contattore, 3 sincronizza l'inversione del contattore 3P 4P 9A~95A AC-3 AC-1
Chint CJX2-N AC Reversing Contactor 3P, 4P 9A~95A 1810, 2510, 3210, 6511, AC-3 AC-1 Coil Voltage 24V,110V,230V,380V characteristic • Current range 09~95A; • AC, DC control coil is optional (DC coil to 38A); • Different types of starters are available: standard motor start contactors, reversible ...
Metro analogico di fattore di potenza di frequenza delle componenti 600V 50A di bassa tensione del puntatore del pannello
Chint 42L6, 6L2 series analog panel pointer meter ammeter, voltmeter, Frequency, Power meter and Power factor meter 42L6, 6L2 series analog meter/panel meter/ pointer analog meter: Introduction: 42L6, 6L2 series instrument consists of measuring circuit, measuring mechanism and indicating device, ...